The
following outcomes
are possible:
If
the visual inspection
determines that
the stucco installation
complies with appropriate
guidelines and moisture
readings are less
than 20%, then no
further action is
necessary.
If
the visual inspection
determines deficiencies
in the stucco installation
and moisture readings
are less than 20%,
then perform repairs
to correct the installation
deficiencies.
If
the visual inspection
determines deficiencies
in the stucco installation
and moisture readings
are between 20%
and 30%, then check
for structural deterioration
as described below
in phase 1 of structural
evaluation, repair
all sources of water
entry and correct
the installation
deficiencies.
If the visual inspection
determines deficiencies
in the stucco installation
and moisture readings
are greater than
30%, then perform
structural investigation
as described below
in phase 1 of structural
evaluation, repair
all sources of water
entry and correct
the installation
deficiencies.